<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>2KW güneş enerjisi inverter Archives - Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</title>
	<atom:link href="https://www.toggo.com.tr/urun-etiketi/2kw-gunes-enerjisi-inverter/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.toggo.com.tr/urun-etiketi/2kw-gunes-enerjisi-inverter/</link>
	<description>Güneşin Enerjisi Sizin olsun</description>
	<lastBuildDate>Sat, 28 Feb 2026 18:36:55 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.toggo.com.tr/wp-content/uploads/2023/02/cropped-Tlogo-32x32.png</url>
	<title>2KW güneş enerjisi inverter Archives - Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</title>
	<link>https://www.toggo.com.tr/urun-etiketi/2kw-gunes-enerjisi-inverter/</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">216981599</site>	<item>
		<title>DEYE 10KW Monofaze String inverter</title>
		<link>https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/</link>
					<comments>https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/#respond</comments>
		
		<dc:creator><![CDATA[Toggo Enerji]]></dc:creator>
		<pubDate>Mon, 09 Sep 2024 17:10:14 +0000</pubDate>
				<guid isPermaLink="false">https://www.toggo.com.tr/?post_type=product&#038;p=6143</guid>

					<description><![CDATA[<p><a href="https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/">DEYE 10KW Monofaze String inverter</a></p>
<p>DEYE 10KW Monofaze String İnverter, büyük ölçekli konutlar ve ticari tesisler için yüksek performanslı, dayanıklı ve verimli bir güneş enerjisi inverteridir.</p>
<p>The post <a href="https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/">DEYE 10KW Monofaze String inverter</a> appeared first on <a href="https://www.toggo.com.tr">Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/">DEYE 10KW Monofaze String inverter</a></p>
<p>DEYE 10KW Monofaze String İnverter, büyük ölçekli konutlar ve ticari tesisler için tasarlanmış, yüksek performanslı bir güneş enerjisi inverteridir. 10KW güç kapasitesi ile enerji ihtiyaçlarınızı eksiksiz karşılar ve maksimum verimlilik sunar. Akıllı izleme ve kontrol özellikleri sayesinde sistem performansınızı anlık olarak takip edebilir ve en verimli şekilde enerji üretimi sağlayabilirsiniz. Yüksek kaliteli ve dayanıklı yapısı, uzun süreli kullanım garantisi verirken, çevre dostu enerji çözümleri sunar.</p>
<p style="text-align: left;"><strong><img decoding="async" class="size-medium wp-image-6146 alignleft" src="https://www.toggo.com.tr/wp-content/uploads/2024/09/init-2-bg-1-300x139.jpg" alt="" width="300" height="139" />Uzaktan kapatma fonksiyonu</strong><br />
<strong>Akıllı İzleme Platformu</strong><br />
Akıllı izleme platformu sayesinde, Deye tam seri invertör ürünleri kaza meydana geldiğinde anında uzaktan kapatmayı destekler. Parametreleri ayarlama ve FW güncellemesi uzaktan yapılır, bu da PV santrali O&amp;M&#8217;sini kolaylaştırır.</p>
<p>&nbsp;</p>
<ul>
<li>2 MPP izleyici, Maksimum verimlilik %97,5&#8217;e kadar</li>
<li>Sıfır export uygulaması, VSG uygulaması</li>
<li>String akıllı izleme (isteğe bağlı)</li>
<li>Geniş çıkış voltajı aralığı</li>
<li>Anti-PID işlevi (İsteğe bağlı)</li>
<li>80V düşük başlangıç ​​voltajı</li>
</ul>
<p><strong><a href="https://www.toggo.com.tr/wp-content/uploads/2024/09/datasheet_sun-9-10.5k-g02p1-eu-am2_240722_en.pdf" target="_blank" rel="noopener">Data Sheet</a></strong></p>
<table>
<colgroup>
<col width="240" />
<col width="170" />
<col width="170" />
<col width="170" /></colgroup>
<tbody>
<tr>
<td width="240">Model</td>
<td width="170">SUN-9K-G02P1-EU-AM2</td>
<td width="170">SUN-10K-G02P1-EU-AM2</td>
<td width="170">SUN-10.5K-G02P1-EU-AM2</td>
</tr>
<tr>
<td width="240">PV String Input Date</td>
<td colspan="3" width="850"></td>
</tr>
<tr>
<td width="240">Max. PV Input Power(kW)</td>
<td width="170">13.5</td>
<td width="170">15</td>
<td width="170">15.8</td>
</tr>
<tr>
<td width="240">Max. PV Input Voltage(V)</td>
<td colspan="3" width="850">550</td>
</tr>
<tr>
<td width="240">Start-up Voltage(V)</td>
<td colspan="3" width="850">80</td>
</tr>
<tr>
<td width="240">MPPT voltage range(V)</td>
<td colspan="3" width="850">70-500</td>
</tr>
<tr>
<td width="240">Rated PV Input voltage(V)</td>
<td colspan="3" width="850">360</td>
</tr>
<tr>
<td width="240">Max. Input Short Circuit Current (A)</td>
<td colspan="3" width="510">39+39</td>
</tr>
<tr>
<td width="240">Max. Operating PV Input Current(A)</td>
<td colspan="3" width="510">26+26</td>
</tr>
<tr>
<td width="240">No. of MPP Trackers/No. of Strings per MPP Tracker</td>
<td colspan="3" width="510">2/2+2</td>
</tr>
<tr>
<td width="240">
<div>AC Output Side</div>
</td>
<td colspan="3" width="850"></td>
</tr>
<tr>
<td width="240">Rated AC Output Active Power(kW)</td>
<td width="170">9</td>
<td width="170">10</td>
<td width="170">11</td>
</tr>
<tr>
<td width="240">Max. AC Output Apparent Power(kVA)</td>
<td width="170">9.9</td>
<td width="170">11</td>
<td width="170">11.55</td>
</tr>
<tr>
<td width="240">Rated AC output current (A)</td>
<td width="170">
<div>41/39.2</div>
</td>
<td width="170">45.5/43.5</td>
<td width="170">47.8/45.7</td>
</tr>
<tr>
<td width="240">Max. AC Output Current(A)</td>
<td width="170">45/43.1</td>
<td width="170">50/47.9</td>
<td width="170">52.5/50.3</td>
</tr>
<tr>
<td width="240">Rated output voltage/range (V)</td>
<td colspan="3" width="850">220/230 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="240">Grid Connection Form</td>
<td colspan="3" width="850">L/N/PE</td>
</tr>
<tr>
<td width="240">Rated Output Grid Frequency/range(Hz)</td>
<td colspan="3" width="850">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="240">Power Factor Adjustment Range</td>
<td colspan="3" width="850">0.8 leading to 0.8lagging</td>
</tr>
<tr>
<td width="240">Total Current Harmonic Distortion THDi</td>
<td colspan="3" width="850">&lt;3%</td>
</tr>
<tr>
<td width="240">DC Injection Current</td>
<td colspan="3" width="850">&lt;0.5%ln</td>
</tr>
<tr>
<td width="240">Efficiency</td>
<td colspan="3" width="850"></td>
</tr>
<tr>
<td width="240">Max. Efficiency</td>
<td colspan="3" width="850">97.7%</td>
</tr>
<tr>
<td width="240">Euro Efficiency</td>
<td colspan="3" width="850">97.2%</td>
</tr>
<tr>
<td width="240">MPPT Efficiency</td>
<td colspan="3" width="850">＞99%</td>
</tr>
<tr>
<td width="240">Equipment Protection</td>
<td colspan="3" width="850"></td>
</tr>
<tr>
<td width="240">DC Polarity Reverse Connection Protection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">AC Output Overcurrent Protection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">AC Output Overvoltage Protection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">AC Output Short Circuit Protection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Thermal Protection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">DC Terminal Insulation Impedance Monitoring</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">DC Component Monitoring</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Ground Fault Current Monitoring</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td>
<div>Arc Fault Circuit Interrupter (AFCI)</div>
</td>
<td colspan="3">
<div>Optional</div>
</td>
</tr>
<tr>
<td width="240">Power Network Monitoring</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Island Protection Monitoring</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Earth Fault Detection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Overvoltage Load Drop Protection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Residual Current (RCD) Detection</td>
<td colspan="3" width="850">yes</td>
</tr>
<tr>
<td width="240">Surge Protection Level</td>
<td colspan="3" width="850">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td width="240">Interface</td>
<td colspan="3" width="850"></td>
</tr>
<tr>
<td width="240">Communication Interface</td>
<td colspan="3" width="850">
<div>RS485/RS232</div>
</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div>
</td>
<td colspan="3">GPRS/WIFI/Bluetooth/4G/LAN(optional)</td>
</tr>
<tr>
<td width="240">General Data</td>
<td colspan="3" width="850"></td>
</tr>
<tr>
<td width="240">Operating Temperature Range (°C)</td>
<td colspan="3" width="850">-25 to +60℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="240">Permissible Ambient Humidity</td>
<td colspan="3" width="850">0~100%</td>
</tr>
<tr>
<td width="240">Permissible Altitude (m)</td>
<td colspan="3" width="850">3000m</td>
</tr>
<tr>
<td width="240">Noise (dB)</td>
<td colspan="3" width="850">≤ 35</td>
</tr>
<tr>
<td width="240">Ingress Protection(IP) Rating</td>
<td colspan="3" width="850">IP 65</td>
</tr>
<tr>
<td width="240">Inverter Topology</td>
<td colspan="3" width="850">Non-Isolated</td>
</tr>
<tr>
<td width="240">Over Voltage Category</td>
<td colspan="3" width="850">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="240">Cabinet Size (WxHxD mm)</td>
<td colspan="3" width="850">330*410*213.5（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="240">Weight [kg]</td>
<td colspan="3" width="850">14.8</td>
</tr>
<tr>
<td width="240">Warranty</td>
<td colspan="3" width="850">5 years</td>
</tr>
<tr>
<td width="240">Type Of Cooling</td>
<td colspan="3" width="850">natural cooling</td>
</tr>
<tr>
<td width="240">Grid Regulation</td>
<td colspan="3" width="850">IEC 61727,IEC 62116,EN 50549,NRS 097,RD 140,UNE 217002,G99</td>
</tr>
<tr>
<td width="240">Safety EMC/Standard</td>
<td colspan="3" width="850">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/">DEYE 10KW Monofaze String inverter</a> appeared first on <a href="https://www.toggo.com.tr">Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.toggo.com.tr/urun/deye-10kw-monofaze-string-inverter-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6143</post-id>	</item>
		<item>
		<title>DEYE 5KW Monofaze String inverter</title>
		<link>https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/</link>
					<comments>https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/#respond</comments>
		
		<dc:creator><![CDATA[Toggo Enerji]]></dc:creator>
		<pubDate>Mon, 09 Sep 2024 16:30:22 +0000</pubDate>
				<guid isPermaLink="false">https://www.toggo.com.tr/?post_type=product&#038;p=6134</guid>

					<description><![CDATA[<p><a href="https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/">DEYE 5KW Monofaze String inverter</a></p>
<p>DEYE 5KW Monofaze String İnverter, yüksek kapasiteli, akıllı izleme özellikli ve dayanıklı yapısıyla ev ve küçük ticari tesisler için mükemmel bir güneş enerjisi inverteridir.</p>
<p>The post <a href="https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/">DEYE 5KW Monofaze String inverter</a> appeared first on <a href="https://www.toggo.com.tr">Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/">DEYE 5KW Monofaze String inverter</a></p>
<p><img fetchpriority="high" decoding="async" class="size-medium wp-image-6136 alignright" src="https://www.toggo.com.tr/wp-content/uploads/2024/09/untitled.892-300x179.webp" alt="" width="300" height="179" />DEYE 5KW Monofaze String İnverter, evler ve küçük ticari tesisler için üstün performans sağlayan yüksek kapasiteli bir güneş enerjisi inverteridir. 5KW gücüyle geniş çaplı enerji ihtiyaçlarını karşılayarak maksimum verimlilik sağlar. Akıllı izleme özellikleriyle enerji üretiminizi her an kontrol altında tutabilir, sistemin performansını optimize edebilirsiniz. Sağlam yapısı, uzun ömürlü bileşenleri ve kolay kurulum özelliği sayesinde DEYE 5KW Monofaze String İnverter, güvenilir bir güneş enerjisi çözümü sunar.</p>
<p><strong>Uzaktan kapatma fonksiyonu</strong><br />
<strong>Akıllı İzleme Platformu</strong><br />
Akıllı izleme platformu sayesinde, Deye tam seri invertör ürünleri kaza meydana geldiğinde anında uzaktan kapatmayı destekler. Parametreleri ayarlama ve FW güncellemesi uzaktan yapılır, bu da PV santrali O&amp;M&#8217;sini kolaylaştırır.</p>
<ul>
<li>2 MPP izleyici, Maksimum verimlilik %97,5&#8217;e kadar</li>
<li>Sıfır export uygulaması, VSG uygulaması</li>
<li>String akıllı izleme (isteğe bağlı)</li>
<li>Geniş çıkış voltajı aralığı</li>
<li>Anti-PID işlevi (İsteğe bağlı)</li>
<li>80V düşük başlangıç ​​voltajı</li>
</ul>
<p><strong><a href="https://www.toggo.com.tr/wp-content/uploads/2024/09/datasheet_sun-3.6-6.2k-g05p1-eu-am2_240722_en.pdf" target="_blank" rel="noopener">Data Sheet</a></strong></p>
<table>
<colgroup>
<col width="264" />
<col width="110" />
<col width="110" />
<col width="110" />
<col width="110" />
<col width="110" />
<col width="110" />
<col width="110" />
<col width="110" /></colgroup>
<tbody>
<tr>
<td width="264">Model</td>
<td width="110">SUN-3.6K-G05P1-EU-AM2</td>
<td width="110">SUN-4K-G05P1-EU-AM2</td>
<td width="110">SUN-4.2K-G05P1-EU-AM2</td>
<td width="110">SUN-4.6K-G05P1-EU-AM2</td>
<td width="110">SUN-5K-G05P1-EU-AM2-</td>
<td width="110">SUN-5.2K-G05P1-EU-AM2</td>
<td width="110">SUN-6K-G05P1-EU-AM2</td>
<td width="110">SUN-6.2K-G05P1-EU-AM2</td>
</tr>
<tr>
<td colspan="9" width="1144">
<div>PV String Input Data</div>
</td>
</tr>
<tr>
<td width="264">
<div>Max. PV Input Power (kW)</div>
</td>
<td width="110">5.4</td>
<td width="110">6</td>
<td width="110">6.3</td>
<td width="110">6.9</td>
<td width="110">7.5</td>
<td width="110">7.8</td>
<td width="110">9</td>
<td width="110">9.3</td>
</tr>
<tr>
<td width="264">
<div>Max. PV Input Voltage (V)</div>
</td>
<td colspan="8" width="880">550</td>
</tr>
<tr>
<td width="264">
<div>Start-up Voltage (V)</div>
</td>
<td colspan="8" width="880">80</td>
</tr>
<tr>
<td width="264">MPPT Voltage Range (V)</td>
<td colspan="8" width="880">70-500</td>
</tr>
<tr>
<td width="264">Rated PV Input Voltage (V)</td>
<td colspan="8" width="880">360</td>
</tr>
<tr>
<td width="264">Max. Operating PV Input Current (A)</td>
<td colspan="8" width="880">18+18</td>
</tr>
<tr>
<td width="264">Max. Input Short Circuit Current (A)</td>
<td colspan="8" width="880">27+27</td>
</tr>
<tr>
<td width="264">No. of MPP Trackers/No. of Strings per MPP Tracker</td>
<td colspan="8" width="880">2/1+1</td>
</tr>
<tr>
<td colspan="9" width="1144">
<div>AC Output Side</div>
</td>
</tr>
<tr>
<td width="264">Rated AC Output Active Power (kW)</td>
<td width="110">3.6</td>
<td width="110">4</td>
<td width="110">4.2</td>
<td width="110">4.6</td>
<td width="110">5</td>
<td width="110">5.2</td>
<td width="110">6</td>
<td width="110">6.2</td>
</tr>
<tr>
<td width="264">Max. AC Output Apparent Power (kVA)</td>
<td width="110">3.96</td>
<td width="110">4.4</td>
<td width="110">4.62</td>
<td width="110">5.06</td>
<td width="110">5.5</td>
<td width="110">5.27</td>
<td width="110">6.6</td>
<td width="110">6.82</td>
</tr>
<tr>
<td width="264">Rated AC Output Current (A)</td>
<td width="110">16.4/15.7</td>
<td width="110">18.2/17.4</td>
<td width="110">19.1/18.3</td>
<td width="110">21/20</td>
<td width="110">22.8/21.8</td>
<td width="110">23.7/22.7</td>
<td width="110">27.3/26.1</td>
<td width="110">28.2/27</td>
</tr>
<tr>
<td width="264">Max. AC Output Current (A)</td>
<td width="110">18/17.3</td>
<td width="110">20/19.2</td>
<td width="110">21/20.1</td>
<td width="110">23/22</td>
<td width="110">25/24</td>
<td width="110">26/24.9</td>
<td width="110">30/28.7</td>
<td width="110">31/29.7</td>
</tr>
<tr>
<td width="264">Rated Output Voltage/Range (V)</td>
<td colspan="8" width="880">220/230 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="264">Grid Connection Form</td>
<td colspan="8" width="880">L/N/PE</td>
</tr>
<tr>
<td width="264">Rated Output Grid Frequency/Range(Hz)</td>
<td colspan="8" width="880">50/45-55, 60/55-65</td>
</tr>
<tr>
<td width="264">Power Factor Adjustment Range</td>
<td colspan="8" width="880">0.8 leading to 0.8 lagging</td>
</tr>
<tr>
<td width="264">Total Current Harmonic Distortion THDi</td>
<td colspan="8" width="880">&lt;3%</td>
</tr>
<tr>
<td width="264">DC Injection Current</td>
<td colspan="8" width="880">&lt;0.5%</td>
</tr>
<tr>
<td colspan="9" width="1144">Efficiency</td>
</tr>
<tr>
<td width="264">Max.Efficiency</td>
<td width="110">97.30%</td>
<td colspan="7" width="770">97.50%</td>
</tr>
<tr>
<td width="264">Euro Efficiency</td>
<td width="110">96.90%</td>
<td colspan="7" width="770">97.00%</td>
</tr>
<tr>
<td width="264">MPPT Efficiency</td>
<td colspan="8" width="880">&gt;99%</td>
</tr>
<tr>
<td colspan="9" width="1144">
<div>Equipment Protection</div>
</td>
</tr>
<tr>
<td width="264">DC Polarity Reverse Connection Protection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">AC Output Overcurrent Protection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">AC Output Overvoltage Protection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">AC Output Short Circuit Protection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Thermal Protection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">DC Terminal Insulation Impedance Monitoring</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">DC Component Monitoring</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Ground Fault Current Monitoring</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Power Network Monitoring</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td>
<div>Arc Fault Circuit Interrupter (AFCI)</div>
</td>
<td colspan="8">
<div>Optional</div>
</td>
</tr>
<tr>
<td width="264">Island Protection Monitoring</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Earth Fault Detection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Overvoltage Load Drop Protection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Residual Current (RCD) Detection</td>
<td colspan="8" width="880">Yes</td>
</tr>
<tr>
<td width="264">Surge Protection Level</td>
<td colspan="8" width="880">TYPE II(DC), TYPE II(AC)</td>
</tr>
<tr>
<td colspan="9" width="1144">Interface</td>
</tr>
<tr>
<td width="264">Communication Interface</td>
<td colspan="8" width="880">RS485/RS232</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div>
</td>
<td colspan="8">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div>
</td>
</tr>
<tr>
<td colspan="9" width="1144">General Data</td>
</tr>
<tr>
<td width="264">Operating Temperature Range (°C)</td>
<td colspan="8" width="880">
<div>-25 to +60℃, &gt;45℃ Derating</div>
</td>
</tr>
<tr>
<td width="264">Permissible Ambient Humidity</td>
<td colspan="8" width="880">0-100%</td>
</tr>
<tr>
<td width="264">Permissible Altitude (m)</td>
<td colspan="8" width="880">3000m</td>
</tr>
<tr>
<td width="264">Noise (dB)</td>
<td colspan="8" width="880">≤35</td>
</tr>
<tr>
<td width="264">Ingress Protection(IP) Rating</td>
<td colspan="8" width="880">IP 65</td>
</tr>
<tr>
<td width="264">Inverter Topology</td>
<td colspan="8" width="880">Non-Isolated</td>
</tr>
<tr>
<td width="264">Over Voltage Category</td>
<td colspan="8" width="880">OVC II(DC), OVC III(AC)</td>
</tr>
<tr>
<td width="264">Cabinet Size (WxHxD mm)</td>
<td colspan="8" width="880">305×280×180 (Excluding Connectors and Brackets)</td>
</tr>
<tr>
<td width="264">Weight (kg)</td>
<td colspan="8" width="880">7.7</td>
</tr>
<tr>
<td width="264">Warranty</td>
<td colspan="8" width="880">5years</td>
</tr>
<tr>
<td width="264">Type of Cooling</td>
<td colspan="8" width="880">Natural Cooling</td>
</tr>
<tr>
<td width="264">Grid Regulation</td>
<td colspan="8" width="880">IEC 61727, IEC 62116, EN 50549, NRS 097, RD 140, UNE 217002, G99</td>
</tr>
<tr>
<td width="264">Safety EMC/Standard</td>
<td colspan="8" width="880">  IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The post <a href="https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/">DEYE 5KW Monofaze String inverter</a> appeared first on <a href="https://www.toggo.com.tr">Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.toggo.com.tr/urun/deye-5kw-monofaze-string-inverter-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6134</post-id>	</item>
		<item>
		<title>DEYE 3KW Monofaze String inverter</title>
		<link>https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/</link>
					<comments>https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/#respond</comments>
		
		<dc:creator><![CDATA[Toggo Enerji]]></dc:creator>
		<pubDate>Mon, 09 Sep 2024 16:18:54 +0000</pubDate>
				<guid isPermaLink="false">https://www.toggo.com.tr/?post_type=product&#038;p=6132</guid>

					<description><![CDATA[<p><a href="https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/">DEYE 3KW Monofaze String inverter</a></p>
<p>DEYE 3KW Monofaze String İnverter, yüksek verimlilik, dayanıklılık ve akıllı izleme özellikleriyle ev ve ticari kullanım için ideal bir güneş enerjisi çözümüdür.</p>
<p>The post <a href="https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/">DEYE 3KW Monofaze String inverter</a> appeared first on <a href="https://www.toggo.com.tr">Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><a href="https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/">DEYE 3KW Monofaze String inverter</a></p>
<p><img decoding="async" class="size-medium wp-image-6125 alignright" src="https://www.toggo.com.tr/wp-content/uploads/2024/09/3-270x300.webp" alt="" width="270" height="300" />DEYE 3KW Monofaze String İnverter, yüksek performans ve güvenilirlik arayan kullanıcılar için tasarlanmış, küçük ve orta ölçekli güneş enerjisi sistemleri için mükemmel bir çözümdür. 3KW gücüyle enerji üretimini en üst düzeye çıkarırken, monofaze yapısıyla evler ve ticari alanlar için idealdir. Akıllı izleme teknolojisi sayesinde enerji üretimini anlık olarak takip edebilir ve maksimum verimlilik sağlayabilirsiniz. Dayanıklı yapısı ve kolay kurulumu ile DEYE 3KW Monofaze String İnverter, uzun ömürlü ve sürdürülebilir bir enerji kaynağı sunar.</p>
<p><strong>Uzaktan kapatma fonksiyonu</strong><br />
<strong>Akıllı İzleme Platformu</strong><br />
Akıllı izleme platformu sayesinde, Deye tam seri invertör ürünleri kaza meydana geldiğinde anında uzaktan kapatmayı destekler. Parametreleri ayarlama ve FW güncellemesi uzaktan yapılır, bu da PV santrali O&amp;M&#8217;sini kolaylaştırır.</p>
<ul>
<li>1 MPP izleyici, Maksimum verimlilik %97,5&#8217;e kadar</li>
<li>Sıfır export uygulaması, VSG uygulaması</li>
<li>String akıllı izleme (isteğe bağlı)</li>
<li>Geniş çıkış voltajı aralığı</li>
<li>Anti-PID işlevi (İsteğe bağlı)</li>
<li>80V düşük başlangıç ​​voltajı</li>
</ul>
<p><a href="https://www.toggo.com.tr/wp-content/uploads/2024/09/datasheet_sun-1-4k-g04p1-eu-am1_240722_en.pdf">Data Sheet</a></p>
<table>
<colgroup>
<col width="240" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" />
<col width="90" /></colgroup>
<tbody>
<tr>
<td width="240">Model</td>
<td width="90">SUN-1K-G04P1-EU-AM1</td>
<td width="90">SUN-1.5K-G04P1-EU-AM1</td>
<td width="90">SUN-2K-G04P1-EU-AM1</td>
<td width="90">SUN-2.2K-G04P1-EU-AM1</td>
<td width="90">SUN-2.5K-G04P1-EU-AM1</td>
<td width="90">SUN-2.7K-G04P1-EU-AM1</td>
<td width="90">SUN-3K-G04P1-EU-AM1</td>
<td width="90">SUN-3.3K-G04P1-EU-AM1</td>
<td width="90">SUN-3.6K-G04P1-EU-AM1</td>
<td width="90">SUN-4K-G04P1-EU-AM1</td>
</tr>
<tr>
<td colspan="11" width="1140">PV String Input Date</td>
</tr>
<tr>
<td width="240">Max. PV Input Power(kW)</td>
<td width="90">1.3</td>
<td width="90">2</td>
<td width="90">2.6</td>
<td width="90">2.9</td>
<td width="90">3.3</td>
<td width="90">3.5</td>
<td width="90">3.9</td>
<td width="90">4.3</td>
<td width="90">4.7</td>
<td width="90">5.2</td>
</tr>
<tr>
<td width="240">Max. PV Input Voltage(V)</td>
<td colspan="10" width="900">550</td>
</tr>
<tr>
<td width="240">Start-up Voltage(V)</td>
<td colspan="10" width="900">80</td>
</tr>
<tr>
<td width="240">MPPT voltage range(V)</td>
<td colspan="10" width="900">70-500</td>
</tr>
<tr>
<td width="240">Rated PV Input voltage(V)</td>
<td colspan="9" width="810">360</td>
<td width="90">420</td>
</tr>
<tr>
<td width="240">
<div>Max. Operating PV Input Current (A)</div>
</td>
<td colspan="10" width="900">20</td>
</tr>
<tr>
<td width="240">
<div>Max. Input Short Circuit Current (A)</div>
</td>
<td colspan="10" width="900">30</td>
</tr>
<tr>
<td width="240">No. of MPP Trackers/No. of Strings  MPP Tracker</td>
<td colspan="10" width="900">1/1</td>
</tr>
<tr>
<td colspan="11" width="1140">
<div>AC Output Side</div>
</td>
</tr>
<tr>
<td width="240">
<div>Rated AC Output Active Power (kW)</div>
</td>
<td width="90">1</td>
<td width="90">1.5</td>
<td width="90">2</td>
<td width="90">2.2</td>
<td width="90">2.5</td>
<td width="90">2.7</td>
<td width="90">3</td>
<td width="90">3.3</td>
<td width="90">3.6</td>
<td width="90">4</td>
</tr>
<tr>
<td width="240">Max. AC Output Apparent Power (kVA)</td>
<td width="90">1.1</td>
<td width="90">1.65</td>
<td width="90">2.2</td>
<td width="90">2.42</td>
<td width="90">2.75</td>
<td width="90">2.97</td>
<td width="90">3.3</td>
<td width="90">3.63</td>
<td width="90">3.96</td>
<td width="90">4.4</td>
</tr>
<tr>
<td width="240">Rated AC output current (A)</td>
<td width="90">4.6/4.4</td>
<td width="90">6.8/6.5</td>
<td width="90">9.1/8.7</td>
<td width="90">10/9.6</td>
<td width="90">11.4/10.9</td>
<td width="90">12.3/11.8</td>
<td width="90">13.7/13.1</td>
<td width="90">15/14.4</td>
<td width="90">16.4/15.7</td>
<td width="90">18.2/17.4</td>
</tr>
<tr>
<td width="240">Max. AC Output Current(A)</td>
<td width="90">5/4.8</td>
<td width="90">7.5/7.2</td>
<td width="90">10/9.6</td>
<td width="90">11/10.6</td>
<td width="90">12.5/12</td>
<td width="90">13.5/13</td>
<td width="90">15/14.4</td>
<td width="90">16.5/15.8</td>
<td width="90">18/17.3</td>
<td width="90">20/19.2</td>
</tr>
<tr>
<td width="240">Rated output voltage/range (V)</td>
<td colspan="10" width="900">220/230 0.85Un-1.1Un</td>
</tr>
<tr>
<td width="240">Grid Connection Form</td>
<td colspan="10" width="900">L+N+PE</td>
</tr>
<tr>
<td width="240">Rated Output Grid Frequency/Range(Hz)</td>
<td colspan="10" width="900">
<div>50/45-55, 60/55-65</div>
</td>
</tr>
<tr>
<td width="240">Power Factor Adjustment Range</td>
<td colspan="10" width="900">0.8 leading to 0.8lagging</td>
</tr>
<tr>
<td width="240">Total Current Harmonic Distortion THDi</td>
<td colspan="10" width="900">&lt;3%</td>
</tr>
<tr>
<td width="240">DC Injection Current</td>
<td colspan="10" width="900">&lt;0.5%ln</td>
</tr>
<tr>
<td colspan="11" width="1140">Efficiency</td>
</tr>
<tr>
<td width="240">Max. Efficiency</td>
<td colspan="6" width="540">97.3%</td>
<td colspan="4" width="360">97.5%</td>
</tr>
<tr>
<td width="240">Euro Efficiency</td>
<td colspan="6" width="540">
<div>96.9%</div>
</td>
<td colspan="4" width="360">97.0%</td>
</tr>
<tr>
<td width="240">MPPT Efficiency</td>
<td colspan="10" width="900">＞99%</td>
</tr>
<tr>
<td colspan="11" width="1140">Equipment Protection</td>
</tr>
<tr>
<td width="240">DC Polarity Reverse Connection Protection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">AC Output Overcurrent Protection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">AC Output Overvoltage Protection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">AC Output Short Circuit Protection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Thermal Protection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">DC Terminal Insulation Impedance Monitoring</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">DC Component Monitoring</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Ground Fault Current Monitoring</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Power Network Monitoring</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td>
<div>Arc Fault Circuit Interrupter (AFCI)</div>
</td>
<td colspan="10">
<div>Optional</div>
</td>
</tr>
<tr>
<td width="240">Island Protection Monitoring</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Earth Fault Detection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Overvoltage Load Drop Protection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Residual Current (RCD) Detection</td>
<td colspan="10" width="900">yes</td>
</tr>
<tr>
<td width="240">Surge Protection Level</td>
<td colspan="10" width="900">TYPE II(DC),TYPE II(AC)</td>
</tr>
<tr>
<td colspan="11" width="1140">Interface</td>
</tr>
<tr>
<td width="240">Communication Interface</td>
<td colspan="10" width="900">RS485/RS232</td>
</tr>
<tr>
<td>
<div>Monitor Mode</div>
</td>
<td colspan="10">
<div>GPRS/WIFI/Bluetooth/4G/LAN(optional)</div>
</td>
</tr>
<tr>
<td colspan="11" width="1140">General Data</td>
</tr>
<tr>
<td width="240">Operating Temperature Range (°C)</td>
<td colspan="10" width="900">-25 to +65℃, &gt;45℃ Derating</td>
</tr>
<tr>
<td width="240">Permissible Ambient Humidity</td>
<td colspan="10" width="900">0~100%</td>
</tr>
<tr>
<td width="240">Permissible Altitude (m)</td>
<td colspan="10" width="900">2000m</td>
</tr>
<tr>
<td width="240">Noise (dB)</td>
<td colspan="10" width="900">≤ 35</td>
</tr>
<tr>
<td width="240">Ingress Protection(IP) Rating</td>
<td colspan="10" width="900">IP 65</td>
</tr>
<tr>
<td width="240">Inverter Topology</td>
<td colspan="10" width="900">Non-Isolated</td>
</tr>
<tr>
<td width="240">Over Voltage Category</td>
<td colspan="10" width="900">OVC II(DC),OVC III(AC)</td>
</tr>
<tr>
<td width="240">Cabinet Size (WxHxD mm)</td>
<td colspan="10" width="900">280mm*310mm*184mm（Excluding connectors and brackets）</td>
</tr>
<tr>
<td width="240">Weight [kg]</td>
<td colspan="10" width="900">6.35</td>
</tr>
<tr>
<td width="240">Warranty</td>
<td colspan="10" width="900">5 Years</td>
</tr>
<tr>
<td width="240">Type Of Cooling</td>
<td colspan="10" width="900">natural cooling</td>
</tr>
<tr>
<td width="240">Grid Regulation</td>
<td colspan="10" width="900">IEC 61727,IEC 62116,CEI 0-21,EN 50549，NRS 097,RD 140,UNE 217002,G98,G99,VDE-AR-N 4105</td>
</tr>
<tr>
<td width="240">Safety EMC/Standard</td>
<td colspan="10" width="900">IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2</td>
</tr>
</tbody>
</table>
<p>The post <a href="https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/">DEYE 3KW Monofaze String inverter</a> appeared first on <a href="https://www.toggo.com.tr">Toggo Enerji Güneş Enerjisi Güneş Paneli MPPT inverter</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.toggo.com.tr/urun/deye-3kw-monofaze-string-inverter-2/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">6132</post-id>	</item>
	</channel>
</rss>
